Main Functions


  • LCD 8 digits

  • Parameters measuring:current,voltage,frequeny,power factor,active power,reactive power,apparent power and 4 quadrant energy
  • Communication:RS485 modbus-RTU
  • Switching value input and relay output
  • Optional functions:
    Total harmonic distortion(THD)

    Up to the 31st harmonic

    Max demand 

    Multi-tariff energy metering

    SOE record

    Alarm

    In-built clock

    J(2DO)

    K(4DI)

    Pulse(2 channel)


    Dimensions and Wirings





  • ACR10R-D16TE4(1.png

  • ACR10R-D16TE4 CTs.png

  • ACR10R-D16TE4 Wiring.png

    Applications

    ACR10R WIRING.png

Charactristics


ACR10R-D16TE4 3 phase energy meter with 3 CTs clamps 24mm
Network
3 phase 4 wire LCD display
voltage
measuring range
AC 57.7V/100V(100V)、220V/380V(400V)
power consumption
≤0.2VA
current
measuring range
200A
power consumption
≤0.2VA
frequency
45hz-65hz
Meauring parameters
Current,voltage,frequeny and power factor
active power,reactive power and apparent power
four quadrant energy
Optional functions
Total harmonic distortion(THD)
Up to the 31st harmonic
Max demand
Multi-tariff energy metering
SOE record
Alarm
in-built clock
J(2DO)
J,K,2 channel pulse,4DI+2DO or 4DI+EP
K(4DI)
Pulse(2 channel)
Accuracy
Frequency:0.05hz ,reactive energy:1 current,voltage:0.5
Power supply
AC85-265V or DC100-350V;DC24V(±10%);DC48V(±10%) power consumption≤10VA
switching value input
4 circuit dry contact
relay output
2 NO contact,capacity:AC 250V/3A,DC 30V/3A
environment
working temperature
-10℃-55℃
storage temperature
-20℃-70℃
relative humudity temperature
≤93%(non-condensing)
altitude
≤2500m
Communication
RS485,Modbus-RTU

Datasheet

Manual


167 ACR10R-Dxxte4 v1.5 Manual.pdf


Certificate



CE of ACR10R.png

2 phase 3 wire 2 channel energy meter with 2 CTs (2 phase 3 wire system)


Rated Voltage
Line to NAC 120
Line to LineAC 208/240V
extended voltage range88%~110%
 Current
Rated RMS current200A
1%-100% of CT Current±1%
Number of Supplied Current Transformers
2pcs
Frequency
60HZ
Grids Supported
L1/L2/N/PE
Communication
RS485,Sunspec protocol
Dimensions
70.5×54.5×39(mm)
Environment
working temperature-30℃-55℃
storage temperature-20℃-70℃
relative humudity temperature≤93%(non-condensing)


Datasheet

Manual