RECOMMENDED PRODUCTS

GIVE US A MESSAGE

Previous: No content
ACR10R-D16TE Single Phase Power Meter with CTs for Solar Inverter

ACR10R-D16TE din rail energy meter with split core open ct clamps is suitable for power monitoring of grid-connected PV power station,power demand side management and other 

applications. It is special designed for solar inverters.


It can measure electrical parameters including current,voltage, active power,reactive power,apparent power,frequency,power factor and so on.


It supports multi-tariff energy metering,4 quadrant energy metering,harmonic analyse and energy monitoring.


Circuit breaker switch 'remote signaling' and 'remote controlling' can be realized with digital input and relay output.

Main Functions


  • LCD 8 digits

  • Parameters measuring:current,voltage,frequeny,power factor,active power,reactive power,apparent power and 4 quadrant energy

  • Communication:RS485 modbus-RTU

  • Switching value input and relay output

  • Optional functions:

    Total harmonic distortion(THD)

    Up to the 31st harmonic

    Max demand 

    Multi-tariff energy metering

    SOE record

    Alarm

    In-built clock

    J(2DO)

    K(4DI)

    Pulse(2 channel)


Dimensions and Wirings


ACR10R-D16TE4(1.png

ACR10R-D16TE4 CTs.png


Applications


ACR10R WIRING.png


Charactristics


ACR10R-D16TE single phase energy meter with CTs clamps 24mm
Network
single phase LCD display
voltage
measuring range
AC 100V、400V
power consumption
≤0.2VA
current
measuring range
200A
power consumption
≤0.2VA
frequency
45hz-65hz
Meauring parameters
Current,voltage,frequeny and power factor
active power,reactive power and apparent power
four quadrant energy






Functions

Total harmonic distortion(THD)
Up to the 31st harmonic
Max demand
Multi-tariff energy metering
SOE record
Alarm
in-built clock
J(2DO)
J,K,2 channel pulse,4DI+2DO or 4DI+EP
K(4DI)
Pulse(2 channel)
Accuracy
Frequency:0.05hz ,reactive energy:1 current,voltage:0.5
Power supply
AC85-265V or DC100-350V;DC24V(±10%);DC48V(±10%) power consumption≤10VA
switching value input
4 circuit dry contact
relay output
2 NO contact,capacity:AC 250V/3A,DC 30V/3A
environment
working temperature
-10℃-55℃
storage temperature
-20℃-70℃
relative humudity temperature
≤93%(non-condensing)
altitude
≤2500m
Communication
RS485,Modbus-RTU

Datasheet

Manual


167 ACR10R-Dxxte4 v1.5 Manual.pdf


Certificate



CE of ACR10R.png

2 phase 3 wire 2 channel energy meter with 2 CTs (2 phase 3 wire system)


Rated Voltage
Line to NAC 120
Line to LineAC 208/240V
extended voltage range88%~110%
 Current
Rated RMS current200A
1%-100% of CT Current±1%
Number of Supplied Current Transformers
2pcs
Frequency
60HZ
Grids Supported
L1/L2/N/PE
Communication
RS485,Sunspec protocol
Dimensions
70.5×54.5×39(mm)
Environment
working temperature-30℃-55℃
storage temperature-20℃-70℃
relative humudity temperature≤93%(non-condensing)